Datashare Internet Engineering

Quality Hosting

UK Windows Hosting PLAN £40PA

EMAIL
WEB
DATABASE

20 Email Acounts
POP3 / SMTP access
Webmail access
Unlimited re-directs
Auto - responders
Spam & virus filter

Any UK or global domain
250GB HD space
2GB monthly bandwidth
Windows Web Server 2003
Full scripting support
Flash & shockwave support
Windows media support
Up to 10 MSSQL databases
Up to 10 MySQL databases
Blue Square DataBlue Square Data
Dell PowerEdge Server

Our websites are hosted in Berkshire, UK, in a datacenter managed by BlueSquare Data, servers are monitored 24/7 by a team of highly qualified engineers. Our servers are so reliable we offer a 99.95% uptime guarentee.

CONTACT US TO ORDER AN ACCOUNT

Hosting is provided in all of our Web Design packages, although many clients come to us specificaly for our reliable hosting services. Because our servers are located in the UK on a highly redundant network our sites are fast. Below you will find full datacenter specifications.

Network
Data Center is connected to the Internet with highly redundant network through multiple Gigabit backbones having multiple peering with other networks.

Hardware Guarantee
Servers deployed at the Data Center includes hardware replacement guarantee. In case of any hardware failure, the hardware is immediately replaced.

Security
Data center located inside its own secure compound, with 2.4 and 3 meter fencing and electric gate entry Equipped & monitored round the clock with closed circuits. Strict access controls are implemented including surveillance cameras, finger-print as well as Key card system in order to manage entries.

Electrical Capacity

Equal Power distribution (60 watts per sq. ft.- 80 watts per sq. ft). Each cabinet 4' x 6' gets 110 volt, 20 amp circuit. The main power sums up to 480 volt, 3 phase. power supplies are now also activated in Multiple DC.

Power
In the unlikely event of a power outage from local power grid, all data centers' power systems are designed to run uninterrupted with the help of Two 2000KW auto-switched power generators and centralized UPS systems. Generators are regularly tested & can be used in emergency event of extended utility power outages.

Precision Environment

Computerized Fully master-planned rise system / HVAC pipe system / Electrically monitoration. HVAC (Heating Ventilation Air Conditioning) systems are N+1 redundant, ensuring that a duplicate system can immediately come online in the event of an HVAC system failure.

Fire Protection System
Wet Risers set in at every square position.FM-200 system is installed. The advanced fire protection system prevents fires from spreading in the unlikely event one should occur.

Technical specifications

  • Own 5mW on-site sub-station
  • 2.5mW backup on-site sub-station
  • Perkins generator connected via ATS systems
  • 2 seperate fibre duct points into the building
  • N+1 PowerWave UPS system
  • N+1 Airedale Air Handling system
  • ~20c +/- 2c data floor temperature
  • 16 Amp feed per equipment rack
  • 24x7 secure entry via PAC-TAG system, with 4 layer entry
  • 24x7 qualified engineers available for remote hands service
  • 450mm heavy duty raised data flooring
We use DELL servers Datacentre provided by Blue Square Data Using Microsoft Windows technology Utilizing MySQL database technology © Copyright 2006 - 2009 Datashare Internet Engineering | All Rights Reserved